Hardness Control Liquid

Deck cabin galley Maintenance-25
Product code  RXSOL-50-5021-025
Qty / Unit25.00 Ltr.
Bulk & custom packaging Pan-India & UAE / Oman supply Technical support included

Application & Usage

Hardness Control is formulated to form a precipitate with calcium ions which will not adhere to metal surfaces but are in a form suitable for blowdown.


 

Procedure

For optimum results dose Hardness Control direct to the boiler via the bypass pot-feeder. The dry powder should be dissolved in hot water (50°C) at a ratio of 1 part powder to twenty parts condensate (e.g. 500 grams/10 litres). Ensure that treatment is fully dissolved before dosing.

Dosage and control

 

 

Phophate test result in pPM PO4

 

 Pressure

 0 - 10

10 - 20

20 - 30

30 - 40

40 - 50

> 50

 Control range

 0-40 Bar
0-588 PSI

 23

11.5 

Satisfactory

Satisfactory

Blow Down

 20-50

41-60 Bar
589-880 PSI 

 17

 5.5

Satisfactory

Blow Down

Blow Down

  15-30

 > 60 Bar
> 880 PSI

 5.5

 Satisfactory

Satisfactory

Blow Down

Blow Down

 10-25

Select row on righthand side for applicable pressure range. Compare test result with comment in table and dose stated amount of product per ton boiler water volume.

These are recommended values based on experience and are in no way intended to replace the boiler manufacturer's specifications or company regulations.

RXSOL Boiler Corrosion Scale Treatment should be fed continuously in order to properly protect the boiler. Boiler Corrosion Scale Treatment can be fed neat or in any convenient dilution made up in soft water or cooled condensate. Boiler Corrosion Scale Treatment should be dosed using individual chemical dosing unit, must not be mixed with oxygen scavengers or condensate system corrosion inhibitors in concentrated form (e.g. concentrated chemical products should not be mixed together).

Sampling and Testing
Boiler Corrosion Scale Treatment is normally used in conjunction with RXSOL Alkalinity Control treatment in a conventional alkaline phosphate treatment programme for HP boilers, where independent control of phosphate and alkalinity control is required.

Dosing and Control
The dosage of Boiler Corrosion Scale Treatment depends on a number of operational factors such as feed-water quality, boiler design and steam rate. Control of Boiler Corrosion Scale Treatment is by a simple test to give the required level of phosphate (as PO4) in the boiler water. A simple Hardness Treatment test kit is available for this purpose. NOTE: Dependent on water quality, Boiler Corrosion Scale Treatment dosed at 0.25 liters/ton will increase the phosphate reserve by the order of 10mg/l.

Technical Specification

Sampling And Testing

A sample of boiler water should be drawn for analysis daily. The sample should always be taken from the same point after blow down, cooled and tested immediately. Follow the Rxsol Hardness Test Kit instructions and fill the Boiler Water Log Form according to result results. It is important that regular testing is carried out to ensure levels of treatment are correct.

Physical Properties :

Appearance        :MILKY LIQ
Corrosive action  : non
pH 1% solution   : 8,8
Flash point         : none

Notes

Benefit and Features

  • Highly active phosphate based compound, economical in use.
  • Easily dissolved in water for dosing.
  • Scale problems due to calcium are eliminated.
  • Maintains sludge in a non-adherent state for ease of blow down.
  • Simple test to determine level of treatment.
  • Can be used for boilers of all pressures.
    Rxsol Hardness Control does not influence the alkalinity in the system